Old 05-02-2006, 12:36 PM   #1 (permalink)
Who You Crappin?
 
Derwood's Avatar
 
Location: Everywhere and Nowhere
Hot Water Heater Overflow Pipe

We have a pretty new (less than 2 years old) hot water heater. Every time someone takes a shower, washes dishes, etc., the tank refills (obviously) but the overflow pipe always ends up dripping. We put a container under the pipe and I would say we are dripping about a pint of water a day. Is this normal? Is there an adjustment that can be made to make it stop refilling before it overflows?
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 05-02-2006, 01:17 PM   #2 (permalink)
Addict
 
Try snugging up the shutoff valve on the overflow. If that doesn't stop the leak you may have to have a new washer. Be sure your overflow pipe is plumbed to the outside. I had an overflow valve blow on my water heater and it blows out steam and near boiling water. Very dangerous. Buy some pvc pipe and send it outdoors. If not corrected the dripping will get worse. (and it could be the popoff valve itself leaking)
newtx is offline  
Old 05-02-2006, 04:13 PM   #3 (permalink)
Unbelievable
 
cj2112's Avatar
 
Location: Grants Pass OR
DO NOT try "snugging up the shutoff valve on the overflow" this is a temperature/pressure relief valve specifically designed to release if the pressure gets to high, not an "overflow valve". Try turning you're hot water heater down to between 120 to 140 degrees farenheit.
cj2112 is offline  
Old 05-02-2006, 06:42 PM   #4 (permalink)
Psycho
 
steveincolumbus's Avatar
 
Location: BFE, Kentucky
check water pressure in house, the valves are made to releave pressure at 150 lbs. If pressure when leaking is normal its the valve, if high, likely to be a one-way-valve or regulator in line preventing backflow, and then you would need a pressure tank of sorts to have a place to expand to.... sence water expands when heated

http://www.factsfacts.com/MyHomeRepa...sureRelief.htm

Last edited by steveincolumbus; 05-02-2006 at 06:48 PM..
steveincolumbus is offline  
Old 05-03-2006, 11:32 AM   #5 (permalink)
Who You Crappin?
 
Derwood's Avatar
 
Location: Everywhere and Nowhere
Quote:
Originally Posted by steveincolumbus
check water pressure in house, the valves are made to releave pressure at 150 lbs. If pressure when leaking is normal its the valve, if high, likely to be a one-way-valve or regulator in line preventing backflow, and then you would need a pressure tank of sorts to have a place to expand to.... sence water expands when heated

http://www.factsfacts.com/MyHomeRepa...sureRelief.htm

Thanks, that's exactly what the pipe looks like. I'm not sure if i'm qualified to fix it myself, but at least I know what to tell a plumber.
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 05-03-2006, 06:53 PM   #6 (permalink)
Addict
 
My bad. cj2112 is correct. I don't know what I was thinking. But do plumb the overflow outside for safety.

Last edited by newtx; 05-03-2006 at 06:54 PM.. Reason: spelling
newtx is offline  
Old 05-31-2006, 08:01 PM   #7 (permalink)
Who You Crappin?
 
Derwood's Avatar
 
Location: Everywhere and Nowhere
so it magically stopped overflowing. Or did it....

It may be a coincidence, but I recently fixed a toilet that shares it's plumbing with the washing machine and hot water heater (common wall). The toilet's water was turned off in the bathroom for several months while I put off fixing it. Seems that the water heater has stopped overflowing since I turned that shutoff back on. Could that be the case?
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 06-01-2006, 04:37 AM   #8 (permalink)
Getting it.
 
Charlatan's Avatar
 
Super Moderator
Location: Lion City
You might want to have it looked at. When mine started doing this it was because the dip tube inside the tank was broken.
__________________
"My hands are on fire. Hands are on fire. Ain't got no more time for all you charlatans and liars."
- Old Man Luedecke
Charlatan is offline  
 

Tags
heater, hot, overflow, pipe, water


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -8. The time now is 12:44 AM.

Tilted Forum Project

Powered by vBulletin® Version 3.8.7
Copyright ©2000 - 2024, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.0 PL2
© 2002-2012 Tilted Forum Project

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360