Hot Water Heater Overflow Pipe

We have a pretty new (less than 2 years old) hot water heater. Every time someone takes a shower, washes dishes, etc., the tank refills (obviously) but the overflow pipe always ends up dripping. We put a container under the pipe and I would say we are dripping about a pint of water a day. Is this normal? Is there an adjustment that can be made to make it stop refilling before it overflows?
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 05-02-2006, 01:17 PM   #2 (permalink)
Addict
 
Try snugging up the shutoff valve on the overflow. If that doesn't stop the leak you may have to have a new washer. Be sure your overflow pipe is plumbed to the outside. I had an overflow valve blow on my water heater and it blows out steam and near boiling water. Very dangerous. Buy some pvc pipe and send it outdoors. If not corrected the dripping will get worse. (and it could be the popoff valve itself leaking)
newtx is offline  
Old 05-02-2006, 04:13 PM   #3 (permalink)
Unbelievable
 
cj2112's Avatar
 
Location: Grants Pass OR
DO NOT try "snugging up the shutoff valve on the overflow" this is a temperature/pressure relief valve specifically designed to release if the pressure gets to high, not an "overflow valve". Try turning you're hot water heater down to between 120 to 140 degrees farenheit.
cj2112 is offline  
Old 05-02-2006, 06:42 PM   #4 (permalink)
Psycho
 
steveincolumbus's Avatar
 
Location: BFE, Kentucky
check water pressure in house, the valves are made to releave pressure at 150 lbs. If pressure when leaking is normal its the valve, if high, likely to be a one-way-valve or regulator in line preventing backflow, and then you would need a pressure tank of sorts to have a place to expand to.... sence water expands when heated

http://www.factsfacts.com/MyHomeRepa...sureRelief.htm

Last edited by steveincolumbus; 05-02-2006 at 06:48 PM..
steveincolumbus is offline  
Old 05-03-2006, 11:32 AM   #5 (permalink)
Who You Crappin?
 
Derwood's Avatar
 
Location: Everywhere and Nowhere
Quote:
Originally Posted by steveincolumbus
check water pressure in house, the valves are made to releave pressure at 150 lbs. If pressure when leaking is normal its the valve, if high, likely to be a one-way-valve or regulator in line preventing backflow, and then you would need a pressure tank of sorts to have a place to expand to.... sence water expands when heated

http://www.factsfacts.com/MyHomeRepa...sureRelief.htm

Thanks, that's exactly what the pipe looks like. I'm not sure if i'm qualified to fix it myself, but at least I know what to tell a plumber.
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 05-03-2006, 06:53 PM   #6 (permalink)
Addict
 
My bad. cj2112 is correct. I don't know what I was thinking. But do plumb the overflow outside for safety.

Last edited by newtx; 05-03-2006 at 06:54 PM.. Reason: spelling
newtx is offline  
Old 05-31-2006, 08:01 PM   #7 (permalink)
Who You Crappin?
 
Derwood's Avatar
 
Location: Everywhere and Nowhere
so it magically stopped overflowing. Or did it....

It may be a coincidence, but I recently fixed a toilet that shares it's plumbing with the washing machine and hot water heater (common wall). The toilet's water was turned off in the bathroom for several months while I put off fixing it. Seems that the water heater has stopped overflowing since I turned that shutoff back on. Could that be the case?
__________________
"You can't shoot a country until it becomes a democracy." - Willravel
Derwood is offline  
Old 06-01-2006, 04:37 AM   #8 (permalink)
Getting it.
 
Charlatan's Avatar
 
Super Moderator
Location: Lion City
You might want to have it looked at. When mine started doing this it was because the dip tube inside the tank was broken.
__________________
"My hands are on fire. Hands are on fire. Ain't got no more time for all you charlatans and liars."
- Old Man Luedecke
Charlatan is offline  
 

Tags
heater, hot, overflow, pipe, water


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -8. The time now is 02:13 AM.

Tilted Forum Project

Powered by vBulletin® Version 3.8.7
Copyright ©2000 - 2025, vBulletin Solutions, Inc.
Search Engine Optimization by vBSEO 3.6.0 PL2
© 2002-2012 Tilted Forum Project

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62