Not sure about your metering. With power off and machine leads disconnected from the solenoids, both solenoids should show continuity. Resistance is going be quite low. If that's good, reconnect the leads to both solenoids, set the main control to 'fill' and cycle to 'warm wash' which should energize both. Change your VOM to AC voltage and see if 120 VAC registers across both coils. If you're not getting 120 VAC across the hot solenoid, that would likely be a fault in the cycle selector (cold/cold, warm/cold, hot/cold) or the main cycle timer.