04-04-2006, 06:41 PM | #1 (permalink) |
Tilted
|
water heater pilot light
Hello everybody, Okay, here is my problem.. I live in a 1981 mobile home, and I am at my wits end with the water heater. I have trouble with high winds blowing the pilot light out... I have visted a local mobile home place and they have these "high wind" caps that they sell... Okay... did that... and... still having the problem. Is there any "ingenious" ways of solving this problem?... a, oh how do you say it... more "industrial"way of solving this? I'm looking for something that will stand up to 100mph winds.. ha.. okay well maybe not that much.. but pretty darn windy. So any ideas or experiences from you guys would be helpful. Thanks alot!
|
04-04-2006, 08:57 PM | #3 (permalink) |
Gentlemen Farmer
Location: Middle of nowhere, Jersey
|
I not too savvy on mobile homes, but if your pilot light is being subjected to ANY WINDS I would think you need to do some insulating.
-bear
__________________
It's alot easier to ask for forgiveness then it is to ask for permission. |
04-05-2006, 03:12 AM | #4 (permalink) | |
Upright
Location: ok
|
Quote:
__________________
Fear not living...fear instead never having lived! |
|
04-05-2006, 07:00 AM | #5 (permalink) |
Riding the Ocean Spray
Location: S.E. PA in U Sofa
|
I suspect it's the hot water heater vent pipe being affected by high wind, and thus causing a "severe" suction into the area where the pilot is burning which blows it out.
You could swap out that old, "dangerous", and "should be obsolete IMO" pilot with a new electronic flame-less ignitor pilot and you won't have this problem Or you could see if there is such a thing as a code authorized, specifically designed vent cap to install on the very top of the vent pipe to reduce the suction effect ...but you have to be very careful not to compromise the draft up the pipe or the exhaust fumes and carbon monoxide will back up into the home and will be very life-threatening. |
04-05-2006, 07:32 AM | #6 (permalink) |
Addict
|
I would suspect the thermocouple as well. If the pilot light goes out when the burner cuts off it would indicate a weak thermocouple. (the flame shuts off and sucks the pilot light out) However if the pilot light only goes out in high wind it would have to be the vent.
|
04-05-2006, 02:45 PM | #7 (permalink) |
Tilted
|
Thanks guys for the response... and yes the pilot light only goes out due to high winds.... no wind.. everything is fine and dandy... So I doubt it is the thermocouple. BadNick... where can i get more information about these electronic flame-less ignitor pilot ?? is this an add-on, or would i need a whole new water heater unit? Well i'm off to once again relight that sucker....Thanks again!
|
04-06-2006, 04:17 PM | #8 (permalink) |
A Storm Is Coming
Location: The Great White North
|
Just stop by your local plumbing supplier with your model and the problem. They should be able to help.
__________________
If you're wringing your hands you can't roll up your shirt sleeves. Stangers have the best candy. |
Tags |
heater, light, pilot, water |
|
|