Electrical? Change switch to Outlet Combo
I do not have an outlet in my bathroom. It would be great for my wife to blow dry her hair in the bathroom, not the bedroom. I took out the switch and wanted to put in a switch with an outlet. There were only two wires in the box. I know this will not work. What can I do so that I will have a working outlet with the switch? Thanks ahead of time.
|
![]() |
![]() |
#2 (permalink) |
Upright
Location: good ol' germany
|
My guess is that the switch only operates on the phase leads, which carry the electrical pontential. The second one, the ground lead, is probably running through the back of the box. In Europe, phase would be blue and ground brown.
You'd need to cut the ground lead and run a short wire out to one terminal of the new outlet and then connect the cut again, so you get like a T-connection. To the other terminal, you connect the phase lead, but keep in mind to tap into it before it reaches the switch, otherwise the switch would operate the light AND the outlet. ![]()
__________________
Die Welt ist dumm und ich erst recht |
![]() |
![]() |
#3 (permalink) |
Junkie
Location: Toronto
|
Are you saying to use the ground wire as a neutral??
In North America, the hot wire is black, the neutral is white, and the ground wire is a bare wire. Even though using the ground as a neutral will work, I don't think that codes allow for this. Under certain circumstances, the ground could become energized and you will be in for a nasty surprise. Not only that but the conductors (hot and neutral) are typically 14 AWG (American Wire Gage), whereas the ground is substantially smaller at 18 AWG. Using the ground as a neutral could conceivably overload the neutral. I would recommend the job be done properly and run a new wire altogether to a separate GFI recepticle in the washroom. (I.e. do not gang the boxes since there will be two separate circuits in one box.) You could put the recepticle in the ideal location for the drier since the switch is most likely just inside the door. OR, Odds are the electrician who wired the house ran the power to the light fixture you could jump a wire off of there. Remove the light fixture and determine which wire brings the power in. The electrician would have connected the white wire of the switch to the hot wire of the feed, then ran the black wire back from the switch to the lamp fixture. The neutrals will all be ganged together and feed the other side of the light. If you have access from the attic, it will be very easy to feed a new piece of Romex into the existing light fixture box, then drop it down inside the wall cavity where you want to locate your recepticle. Then connect the GFI recepticle. Job finished and properly to boot. |
![]() |
![]() |
#4 (permalink) |
Détente
Location: AWOL in Edmonton
|
I agree with the above posts, the two wires are to switch the light, and I would say that they shouldn't be used for anything else.
It also depends on the circuit itself. Years and years ago, my dad performed a similar operation, running a receptcle from the junction box above the light. It just so happened that the orginal electrician who wired up the place in the first place was short on breakers and had run an extensive lighting circuit throughout the top floor, where the bathroom was located. The result, after my dad ran an outlet off of it for the same reason you have, to run a blow dryer, was somewhat problematic. Sure, mom could dry her hair, but if the lights were on in their bedroom, the hallway, and my sister's room, the breaker snapped off. And then I was usually sent to the basement to flip it back on. A few summers ago while doing some renovations, one of my friends from highschool who became an electrician and I rewired my parents house. A new main panel, replacing the scary old wire, and running about 8 new circuits. What I learned was that if you have an open attic or exposed joists (or a drop ceiling) in the basement, it really is pretty easy to run wires to where you need them. A little coiled wire snake was the only tool I had to buy (I already had a multimeter and required hand tools). So what I'm rambling about here is that if at all possible, run a fresh circuit, or at least make sure that the existing light circuit will handle the load. |
![]() |
![]() |
#5 (permalink) |
Tone.
|
before we get too excited about running a new circuit. . .
how old is your house? if it was built late enough to use romex (nm-b) wire, then you probably have a neutral wire somewhere close by. Some people (and don't get me wrong, they should NOT do this) split the hot and neutral wires before the switch box. Then they run the black wire in the box while routing the white wire around the box. This means they don't have to cut the white wire. The way you're supposed to do it is to run the romex into the box, cut all the wires, install the switch, wirenut the white wires together behind the switch, and do the same to the ground wires. I'd check where the black wire comes into the box, look through the slot in the box and see if you see the white wire sitting there. |
![]() |
![]() |
#6 (permalink) | |
Upright
Location: good ol' germany
|
Quote:
But that's not very important for a light bulb. iHawk
__________________
Die Welt ist dumm und ich erst recht |
|
![]() |
![]() |
#7 (permalink) |
Insane
Location: New Jersey
|
Guys, Thanks for the replies. It sounded like such a simple thing for me to do. You are making me think I should have a professional com ein and do it for me. I thought it would be as simple as relacing an outlet or switch.
1. My house (in NJ, USA) was built in 1954. The wiring in the bathroom is the original. 2. There are only 2 wires, a black and a white. NO grounding wire. |
![]() |
![]() |
#8 (permalink) | |
Junkie
Location: Toronto
|
Quote:
There's only two wires in the box where the switch is correct? One black, one white, and they both are connected to the switch correct? If correct on both counts, the electrician has fed the light, then used one wire to bring the hot from the light via the white wire, then return it from the other side of the switch via the back wire. It's done all the time. If correct on both counts, then under the light fixture will be the feed. Do you have access from the attic? 1954 probably had no ground wires, but at least you are not knob and tube. |
|
![]() |
![]() |
#9 (permalink) |
Tone.
|
1954 would probably make it armored cable, which uses the flexible metal conduit as the ground. Wouldn't be surprised if there were a pigtail coming off of your outlets and screwed into the back of the outlet box.
I'd probably have an electrician look at it for your first time simply because codes were looser in '54 and I've actually seen some rubber-sheathed (not knob&tube, but rubber-infused cloth weave) insulation that, just like knob&tube, can break down after 25 years and be dangerous. It wouldn't be a bad idea to have sparky check that. . . |
![]() |
![]() |
#11 (permalink) |
It's a girly girl!
Location: OH, USA
|
being that I just re-ran all the electrical wiring in my house (35years old, but definitly not to code even when constructed) I can say that wiring is not as simple as many would lead you to believe. I agree that you should check with an electrician in your situation being that you seem to have little experience in this subject/field. Best of luck to you, and whatever you do, don't let the sparky out of your sight while he's in your house. I've had more than one try and charge me for things they didn't do (I love X10's wireless cameras) www.X10.com